Customization: | Available |
---|---|
Certification: | CE, ISO |
Place Style: | Horizontal |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL | ZD-ATGX-C-1200 | ZD-ATGX-C-1500 | ZD-ATGX-C-1800 |
Rated power (kW) | 600 | 900 | 1200 |
Rated voltage (V) | 380/50HZ | 380/50HZ | 380/50HZ |
Maximum heating temperature in the low-temperature section (ºC) | 600 | 600 | 600 |
Number of temperature zones in the low-temperature section (pcs) | 5 | 6 | 6 |
Maximum heating temperature in the high-temperature section (ºC) | 850 | 850 | 850 |
Number of temperature zones in the high-temperature section (pcs.) | 5 | 6 | 6 |
Heating drum diameter (mm) | Φ1200 | Φ1500 | Φ1800 |
Applicable gas | CARBON DIOXIDE/AIR/STEAM | CARBON DIOXIDE/AIR/STEAM | CARBON DIOXIDE/AIR/STEAM |
Cooling water flow rate (m3/h) | 20~60 | 20~70 | 20~80 |
Cooling water operating pressure (MPa) | ≤0.4 | ≤0.4 | ≤0.4 |
Material discharge temperature | ≤80 | ≤80 | ≤80 |
Heating mode | ELECTRICAL HEATING | ELECTRICAL HEATING | ELECTRICAL HEATING |
Capacity (kg/h) | 350-450(Depending on specific materials and production processes) |
500-600(Depending on specific materials and production processes) |
700-800(Depending on specific materials and production processes) |